sscv.Rd
It calculates sample size for the bioequivalence test on ratio using coefficient of variation (CV).
sscv(CV, DesignNo = 1, True.R = 1, Alpha = 0.1, Beta = 0.2,
ThetaL = 0.8, ThetaU = 1.25, nMax = 999999)
Coefficient of Variation (%)
Crossover design number.
Design Number (treatment x sequence x period)
1 2x2x2 : RT TR
2 2x4x2 (Balaam Design) : TT RR RT TR
3 2x2x3 (Two-sequence Dual Design): TRR RTT
4 2x2x4 : TRRT RTTR
5 2x4x4 : TTRR RRTT TRRT RTTR
6 3x6x3 (William Design for 3 treatments) + carry-over effect
: RBA ARB BAR ABR BRA RAB
7 3x6x3 (William Design for 3 treatments) - carry-over effect
: RBA ARB BAR ABR BRA RAB
8 4x4x4 (William Design for 4 treatments) + carry-over effect
: RCAB ARBC BACR CBRA
9 4x4x4 (William Design for 4 treatments) - carry-over effect
: RCAB ARBC BACR CBRA
True ratio of test/reference
Alpha error level
Beta error level
Lower limit of equivalence criteria
Upper limit of equivalence criteria
Maximum subject number (sample size) per group
It calculates sample size (n per group) with CV
, Alpha
, and Beta
for bioequivalence test.
Returns sample size (n per group) for bioequivalence test with ratio criteria.
sscv(25)
#> [1] 11
#> attr(,"Power")
#> [1] 0.8020953