powcv.Rd
It calculates power for the bioequivalence test on ratio using coefficient of variation (CV).
powcv(n, CV, DesignNo = 1, True.R = 1, Alpha = 0.1, ThetaL = 0.8, ThetaU = 1.25)
Sample size, n per group
Coefficient of Variation (%)
Crossover design number.
Design Number (treatment x sequence x period)
1 2x2x2 : RT TR
2 2x4x2 (Balaam Design) : TT RR RT TR
3 2x2x3 (Two-sequence Dual Design): TRR RTT
4 2x2x4 : TRRT RTTR
5 2x4x4 : TTRR RRTT TRRT RTTR
6 3x6x3 (William Design for 3 treatments) + carry-over effect
: RBA ARB BAR ABR BRA RAB
7 3x6x3 (William Design for 3 treatments) - carry-over effect
: RBA ARB BAR ABR BRA RAB
8 4x4x4 (William Design for 4 treatments) + carry-over effect
: RCAB ARBC BACR CBRA
9 4x4x4 (William Design for 4 treatments) - carry-over effect
: RCAB ARBC BACR CBRA
True ratio of test/reference
Alpha error level
Lower limit of equivalence criteria
Upper limit of equivalence criteria
It calculates power of sample size (n per group) with CV
.
Returns power [0, 1)
powcv(12, 25)
#> [1] 0.8438499